Assessment of thoron contribution to indoor radon exposure in Canada.
- Authors
Chen, Jing
- Abstract
From 2007 to 2013, simultaneous radon (222Rn) and thoron (220Rn) measurements were conducted in a total of 3534 residential homes in 34 metropolitan areas covering 71% of the Canadian population. While radon levels were above the detector's detection limit in almost all homes, thoron concentrations were measurable in only 1738 homes. When analysis was limited to homes where thoron concentrations exceeded the detection limit, a pooled analysis confirmed that thoron is log-normally distributed in the indoor environment, and the distribution was characterized by a population-weighted geometric mean of 13 Bq/m3 and a geometric standard deviation of 1.89. Thoron contribution to indoor radon dose varied widely, ranging from 1.3 to 32% geographically. This study indicated that on average, thoron contributes 4% of the radiation dose due to total indoor radon exposure (222Rn and 220Rn) in Canada.
- Subjects
CANADA; THORON; RADON; DETECTION limit; METROPOLITAN areas; RADIATION doses; STANDARD deviations
- Publication
Radiation & Environmental Biophysics, 2022, Vol 61, Issue 1, p161
- ISSN
0301-634X
- Publication type
Article
- DOI
10.1007/s00411-021-00956-0