We found a match
Your institution may have access to this item. Find your institution then sign in to continue.
- Title
The remaining dentin thickness investigation of the attempt to remove broken instrument from mesiobuccal canals of maxillary first molars with virtual simulation technique.
- Authors
Qian Yang; Gary Shun-Pan Cheung; Ya Shen; Dingming Huang; Xuedong Zhou; Yuan Gao
- Abstract
Background: To investigate differences in the estimated minimum remaining dentin thickness (RDT) between periapical radiographs using the paralleling and parallax technique, after simulated removal of broken instrument from the mesiobuccal (MB) canal of maxillary first molar in virtual simulation model. The 3D measurement was taken as the standard for comparison. Methods: Thirty-six maxillary first molars were scanned by micro-CT and reconstructed as 3-dimensional (3D) model. A virtual fragment of an instrument was created within the MB canal in software. Removal of the broken instrument was simulated in both the 3D and 2D dataset. Then, the models of all specimens were submitted to 2D and 3D measurements for the lowest (RDT) value in each. Differences in the values between the paralleling and parallax radiographic technique and the 3D-RDT value were analyzed with two-way Analysis of Variance. The Intra-class Correlation Coefficient (ICC) was used to assess consistency of the RDT measurements between the two periapical radiographic and techniques and 3D analysis. Results: There was significant difference between RDT value obtained from the paralleling technique and 3D-RDT. There were no differences between RDT obtained from parallax (angled) technique and 3D-RDT. The ICC of RDT values between paralleling technique and 3D measurement were lower than 0.75. ICC between angled radiographs and 3D technique was close to 0.75. The optimal horizontal angle for the parallax technique was about 21°. Conclusions: The virtual simulation technique can provide valuable insight into the benefit/risk analysis before removal of a broken instrument. Parallel radiographs overestimate the actual remain dentin thickness in mesiobuccal canals of maxillary first molars, whereas the parallel technique would give a closer estimate to the actual thickness at a projection angle of about 21°.
- Subjects
DENTIN anatomy; MOLARS; COMPUTER simulation; COMPUTED tomography; ROOT canal treatment; REOPERATION; ANALYSIS of variance; INTRACLASS correlation; TREATMENT failure; DATA analysis software
- Publication
BMC Oral Health, 2015, Vol 15, Issue 1, p1
- ISSN
1472-6831
- Publication type
Article
- DOI
10.1186/s12903-015-0075-x