- Title
LC/MS determination of bisphenol A in river water using a surface-modified molecularly-imprinted polymer as an on-line pretreatment device.
- Authors
Watabe, Yoshiyuki; Hosoya, Ken; Tanaka, Nobuo; Kondo, Takuya; Morita, Masatoshi; Kubo, Takuya
- Abstract
A new analytical method for the determination of bisphenol A (BPA) by LC/MS was developed and applied to environmental water samples. Quantitative MS detection of BPA was carried out in the negative mode. In order to preconcentrate the target compound yet prevent serious contamination of the water samples from the experimental environment, we employed column switching HPLC coupled with a pretreatment column of surface-modified molecularly-imprinted polymers. The recovery of BPA from a spiked environmental water sample was 102% and the repeatability of actual determinations of water samples containing 20 ng/L of BPA was 5.4% RSD. By modifying the surfaces of the molecularly-imprinted polymer particles packed in the pretreatment column, interference from the water samples was effectively removed, resulting in a significant increase in sensitivity and more reliable results. This method was successfully applied to the trace determination of BPA in environmental water samples using LC/MS.
- Subjects
BISPHENOL A; WATER analysis; PHENOLS; POLYMERS; MOLECULES
- Publication
Analytical & Bioanalytical Chemistry, 2005, Vol 381, Issue 6, p1193
- ISSN
1618-2642
- Publication type
Article
- DOI
10.1007/s00216-004-3031-1