- Title
Triple-loop reentrant atrial tachycardia originated after pulmonary vein isolation.
- Authors
Takigawa, Masateru; Denis, Arnaud; Frontera, Antonio; Derval, Nicolas; Sacher, Frédéric; Jaïs, Pierre; Haïssaguerre, Michel; Sacher, Frédéric; Jaïs, Pierre; Haïssaguerre, Michel
- Abstract
A case study of a 67-year-old woman with prior pulmonary vein (PV) isolation for paroxysmal atrial fibrillation presented with persistent atrial tachycardia (AT). Topics discussed include mapping of AT was done with the Orion catheter and Rhythmia system, treating with minimal radio frequency applications, and discussing the difference between the total cycle length (CL) and post-pacing-interval (PPI).