Image quality and dose reduction opportunity of deep learning image reconstruction algorithm for CT: a phantom study.
- Authors
Greffier, Joël; Hamard, Aymeric; Pereira, Fabricio; Barrau, Corinne; Pasquier, Hugo; Beregi, Jean Paul; Frandon, Julien
- Abstract
<bold>Objectives: </bold>To assess the impact on image quality and dose reduction of a new deep learning image reconstruction (DLIR) algorithm compared with a hybrid iterative reconstruction (IR) algorithm.<bold>Methods: </bold>Data acquisitions were performed at seven dose levels (CTDIvol : 15/10/7.5/5/2.5/1/0.5 mGy) using a standard phantom designed for image quality assessment. Raw data were reconstructed using the filtered back projection (FBP), two levels of IR (ASiR-V50% (AV50); ASiR-V100% (AV100)), and three levels of DLIR (TrueFidelity™ low, medium, high). Noise power spectrum (NPS) and task-based transfer function (TTF) were computed. Detectability index (d') was computed to model a large mass in the liver, a small calcification, and a small subtle lesion with low contrast.<bold>Results: </bold>NPS peaks were higher with AV50 than with all DLIR levels and only higher with DLIR-H than with AV100. The average NPS spatial frequencies were higher with DLIR than with IR. For all DLIR levels, TTF50% obtained with DLIR was higher than that with IR. d' was higher with DLIR than with AV50 but lower with DLIR-L and DLIR-M than with AV100. d' values were higher with DLIR-H than with AV100 for the small low-contrast lesion (10 ± 4%) and in the same range for the other simulated lesions.<bold>Conclusions: </bold>New DLIR algorithm reduced noise and improved spatial resolution and detectability without changing the noise texture. Images obtained with DLIR seem to indicate a greater potential for dose optimization than those with hybrid IR.<bold>Key Points: </bold>• This study assessed the impact on image quality and radiation dose of a new deep learning image reconstruction (DLIR) algorithm as compared with hybrid iterative reconstruction (IR) algorithm. • The new DLIR algorithm reduced noise and improved spatial resolution and detectability without perceived alteration of the texture, commonly reported with IR. • As compared with IR, DLIR seems to open further possibility of dose optimization.
- Subjects
IMAGE reconstruction algorithms; DEEP learning; IMAGE reconstruction; MULTIDETECTOR computed tomography; REAR-screen projection; SIGNAL convolution; COMPUTERS in medicine; DIAGNOSTIC imaging; RADIATION doses; COMPUTED tomography; IMAGING phantoms; ALGORITHMS
- Publication
European Radiology, 2020, Vol 30, Issue 7, p3951
- ISSN
0938-7994
- Publication type
journal article