We found a match
Your institution may have access to this item. Find your institution then sign in to continue.
- Title
Inter-observer variation and diagnostic efficacy of apparent diffusion coefficient (ADC) measurements obtained by diffusion-weighted imaging (DWI) in small renal masses.
- Authors
Ponhold, Lothar; Javor, Domagoj; Heinz-Peer, Gertraud; Sevcenco, Sabina; Hofstetter, Martin; Baltzer, Pascal Andreas
- Abstract
<bold>Background: </bold>Diffusion-weighted imaging (DWI) is increasingly used to diagnose renal lesion subtypes. Especially in small renal masses, identification of less aggressive tumor types is of clinical interest, as active surveillance strategies can be applied. <bold>Purpose: </bold>To evaluate the inter-observer variation and diagnostic efficacy of apparent diffusion coefficient (ADC) measurements obtained by DWI in small renal masses ≤4 cm (SRM). <bold>Material and Methods: </bold>This retrospective IRB-approved study included 39 patients (46 SRM: 12 benign, 34 malignant). All underwent a 3 T DWI of SRM prior to surgery. Two radiologists independently analyzed all imaging data by three measurements. Limits of agreement, intraclass correlation coefficients (ICC), group comparisons by t-tests, and ROC analysis were performed. <bold>Results: </bold>Reliability of ADC measurements was very high with an ICC of >0.9 for both observers. Inter-rater reliability was high with an ICC of 0.82. Limits of agreement for average ADC values between both observers were -23.5% to 38.3% with a mean difference of 7.5% between both observers. No significant differences were found between benign and malignant lesions (P value Observer 1: 0.362, Observer 2: 0.622). Papillary carcinoma showed lower ADC values compared to non-papillary carcinoma (P value Observer 1: 0.008, Observer 2: 0.012). Consequently, ROC analysis revealed a significant (P < 0.001, respectively) area under the ROC curve of 0.853 (Observer 1) and 0.837 (Observer 2) without significant differences between both readers (P = 0.772). <bold>Conclusion: </bold>ADC measurements of SRM at 3 T show a high reproducibility and differentiate papillary from non-papillary carcinoma subtypes. However, measurement variability may limit the application of fixed ADC thresholds for lesion diagnosis.
- Subjects
KIDNEY tumors; TUMOR diagnosis; DIFFUSION magnetic resonance imaging; INTER-observer reliability; INTRACLASS correlation; MAGNETIC resonance imaging; RESEARCH evaluation; RESEARCH bias; CONTRAST media
- Publication
Acta Radiologica, 2016, Vol 57, Issue 8, p1014
- ISSN
0284-1851
- Publication type
journal article
- DOI
10.1177/0284185115610934