We found a match
Your institution may have access to this item. Find your institution then sign in to continue.
- Title
Two-Year Outcome with Nobel Direct® Implants: A Retrospective Radiographic and Microbiologic Study in 10 Patients.
- Authors
Van de Velde, Tommie; Thevissen, Eric; Persson, G. Rutger; Johansson, Carina; De Bruyn, Hugo
- Abstract
Introduction: The Nobel Direct® implant (Nobel Biocare AB, Göteborg, Sweden) was developed to minimize marginal bone resorption and to result in “soft tissue integration” for an optimized aesthetic outcome. However, conflicting results have been presented in the literature. The aim of this present study was to evaluate the clinical and microbiologic outcomes of Nobel Direct implants. Materials and Methods: Ten partially edentulous subjects without evidence of active periodontitis (mean age 55 years) received 12 Nobel Direct implants. Implants were loaded with single crowns after a healing period of 3 to 6 months. Treatment outcomes were assessed at month 24. Routine clinical assessments, intraoral radiographs, and microbiologic samplings were made. Histologic analysis of one failing implant and chemical spectroscopy around three unused implants was performed. Paired Wilcoxon signed-rank test was used for the evaluation of bone loss; otherwise, descriptive analysis was performed. Results: Implants were functionally loaded after 3 to 6 months. At 2 years, the mean bone loss of remaining implants was 2.0 mm (SD ± 1.1 mm; range: 0.0–3.4 mm). Three out of 12 implants with an early mean bone loss >3 mm were lost. The surviving implants showed increasing bone loss between 6 and 24 months ( p = .028). Only 3 out of the 12 implants were considered successful and showed bone loss of <1.7 mm after 2 years. High rates of pathogens, including Aggregatibacter actinomycetemcomitans, Fusobacterium spp., Porphyromonas gingivalis, Pseudomonas aeruginosa, and Tanerella forsythia, were found. Chemical spectroscopy revealed, despite the normal signals from Ti, O, and C, also peaks of P, F, S, N, and Ca. A normal histologic image of osseointegration was observed in the apical part of the retrieved implant. Conclusion: Radiographic evidence and 25% implant failures are indications of a low success rate. High counts and prevalence of significant pathogens were found at surviving implants. Although extensive bone loss had occurred in the coronal part, the apical portion of the implant showed some bone to implant integration.
- Subjects
DENTAL implants; NOBEL Biocare AB; BONE resorption; PERIODONTITIS; OSSEOINTEGRATION
- Publication
Clinical Implant Dentistry & Related Research, 2009, Vol 11, Issue 3, p183
- ISSN
1523-0899
- Publication type
Article
- DOI
10.1111/j.1708-8208.2008.00112.x