We found a match
Your institution may have access to this item. Find your institution then sign in to continue.
- Title
Distinguishing Ventricular Arrhythmia Originating from the Right Coronary Cusp, Peripulmonic Valve Area, and the Right Ventricular Outflow Tract: Utility of Lead I.
- Authors
EBRILLE, ELISA; CHANDRA, VISHNU M.; SYED, FAISAL; DEL CARPIO MUNOZ, FREDDY; NANDA, SUDIP; HAI, JO JO; CHA, YONG‐MEI; FRIEDMAN, PAUL A.; HAMMILL, STEPHEN C.; MUNGER, THOMAS M.; VENKATACHALAM, K.L.; PACKER, DOUGLAS L.; ASIRVATHAM, SAMUEL J.
- Abstract
ECG Lead I and Outflow Tract Arrhythmia Introduction Outflow tract ventricular arrhythmia (OTVA) can be complicated to target for ablation when originating from either the periaortic or pulmonary valve (PV) region. Both sites may present with a small R wave in lead V1. However, the utility of lead I in distinguishing these arrhythmia locations is unknown. Methods and Results Thirty-six consecutive patients (mean age 41 ± 14 years, 13 male) underwent catheter ablation for OTVA. OTVA origin was determined from intracardiac electrogram tracings and electroanatomic maps. Observers blinded to results measured QRS waveform amplitude and duration from standard 12-lead ECG tracings. Measurements with highest diagnostic performance were modeled into an algorithm. Sites of successful ablation were anterior right ventricular outflow tract (RVOT; n = 6), posterior RVOT (n = 4), PV (n = 18), and right coronary cusp (RCC; n = 8). Highest performing surface ECG discriminators were from lead I to V1 vectors: RCC, lead I R wave ≥ 1.5 mV, and V1 R wave ≥2.0 mV (sensitivity 87%, specificity 93%); PV, V1 R wave > 0 mV, and lead I R/(R+S) ≤ 0.75 (sensitivity 78%, specificity 72%); anterior RVOT, V1 R wave = 0 mV, and lead I R/(R+S) <0.4 (sensitivity 67%, specificity 97%); posterior RVOT, V1 R wave > 0 mV, and lead I R/(R+S) > 0.75 (sensitivity 75%, specificity 84%). Sequential algorithmic application of these criteria resulted in an overall accuracy of 72% in predicting site of OTVA origin. Conclusions A relatively large R wave in lead I is seen with RCC origin but not PV origin. A sequential algorithm has limited but potentially significant value beyond assessment of lead I in approaching OTVA.
- Subjects
MINNESOTA; ALGORITHMS; ANALYSIS of variance; CATHETER ablation; ELECTROCARDIOGRAPHY; ELECTROPHYSIOLOGY; STATISTICS; T-test (Statistics); U-statistics; RETROSPECTIVE studies; RECEIVER operating characteristic curves; DESCRIPTIVE statistics; VENTRICULAR arrhythmia; THERAPEUTICS
- Publication
Journal of Cardiovascular Electrophysiology, 2014, Vol 25, Issue 4, p404
- ISSN
1045-3873
- Publication type
Article
- DOI
10.1111/jce.12330