We found a match
Your institution may have access to this item. Find your institution then sign in to continue.
- Title
Transcatheter mitral valve-in-valve replacement transeptally using a novel balloon-expandable device.
- Authors
Drakopoulou, Maria; Latsios, George; Synetos, Andreas; Benetos, Georgios; Soulaidopoulos, Stergios; Oikonomou, Georgios; Apostolos, Anastasios; Aggeli, Konstantina; Lozos, Vasilios; Lymperiadis, Dimitrios; Tsioufis, Konstantinos; Toutouzas, Konstantinos
- Abstract
We describe a patient with symptomatic severe mitral regurgitation, due to a failed 33-mm Epic (St. Jude Medical, St. Paul, MN) bioprosthetic heart valve surgically implanted 10-year before. For this specific purpose, we implanted a novel balloon-expandable transcatheter heart valve, the MyVal (Meril Life Science, Vapi, India). To the best of our knowledge, this is the second case describing the implantation of MyVal in a degenerative, surgically placed bioprosthesis.
- Publication
Journal of Cardiac Surgery, 2022, Vol 37, Issue 10, p3376
- ISSN
0886-0440
- Publication type
Case Study
- DOI
10.1111/jocs.16819