Using Variable Speed Control on Pump Application.
- Authors
Spahiu, Aida; Zavalani, Orion; Uka, Altin
- Abstract
Pumps are one of the most common variable speed drive (VSD) system applications and special interest has focused on improving their energy efficiency by using variable speed control instead of throttling or other less efficient flow control methods. Pumps are the single largest user of electricity in industry in the European Union, consuming 160 TWh per annum of electricity and accounting for 79 million tonnes of carbon dioxide (CO2) emissions [1]. Centrifugal pumps are the most likely pump style to provide a favorable return based on energy savings when applied with a variable speed drive. To help illustrate this, are conducted benchmark testing to document various head and flow scenarios and their corresponding effect on energy savings. Paper shows the relationship of static and friction head in the energy efficiency equation and the effect of motor, pump and VSD efficiencies. The received results are good reference points for engineers and managers of water sector in Albania to select the best prospects for maximizing efficiency and energy savings.
- Subjects
ALBANIA; PUMPING machinery; ENERGY consumption; VARIABLE speed limits; EUROPEAN Union; CARBON dioxide mitigation
- Publication
ILIRIA International Review, 2012, Issue 1, p252