We found a match
Your institution may have access to this item. Find your institution then sign in to continue.
- Title
Performance of free-breathing dynamic T1-weighted sequences in patients at risk of developing motion artifacts undergoing gadoxetic acid–enhanced liver MRI.
- Authors
Park, So Hyun; Yoon, Jeong Hee; Park, Jin Young; Shim, Young Sup; Lee, Sang Min; Choi, Seung Joon; Nickel, Marcel Dominik; Lee, Jeong Min
- Abstract
Objectives: To evaluate the recall rate and performance of free-breathing T1W dynamic imaging in patients who underwent gadoxetic acid–enhanced liver MRI. Methods: We retrospectively reviewed patients who underwent free-breathing dynamic T1WI liver MRI using Cartesian (XD-VIBE) or self-gated radial (SG-GRASP) sequences at two institutions. Four radiologists independently reviewed the overall image quality, streak, and motion artifacts for precontrast, arterial, and portal venous phases on a 4-point scale. Hepatic observations were annotated and assessed according to LI-RADS v2018. Results: In total, 360 patients were included (XD-VIBE [n = 253], SG-GRASP [n = 107]). The overall image quality of free-breathing T1WI was 3.4 ± 0.4, 3.2 ± 0.4, and 3.5 ± 0.4 for precontrast, arterial, and portal venous phases, respectively. The actual recall rate was 0.6% (2/360). The SG-GRASP group showed fewer motion artifacts and more streak artifacts than the XD-VIBE group in all phases (p < 0.001 for all). The overall image quality was not significantly different between the two sequences in arterial (3.2 ± 0.4 in both, p = 0.607) and portal venous phases (3.5 ± 0.4 in XD-VIBE, 3.4 ± 0.4 in SG-GRASP, p = 0.214). Two sequences did not show significant differences in the lesion detection rate (figure of merit, FOM: 0.67 vs. 0.68, p = 0.876) or diagnostic performance for hepatocellular carcinoma (FOM: 0.55 vs. 0.62, p = 0.105). Conclusions: Both XD-VIBE and SG-GRASP provided sufficient image quality for patients at risk of developing motion artifacts, without significant differences in image quality or the lesion detection rate between sequences. Key Points: • The overall image quality of free-breathing T1-weighted images using Cartesian or radial sequences was 3.4 ± 0.4, 3.2 ± 0.4, and 3.5 ± 0.4 for precontrast, arterial, and portal venous phases, respectively. • Only 0.3% (1/360) had undiagnostic exams and the actual recall rate was 0.6% (2/360) in patients who underwent free-breathing dynamic T1WI. • The overall lesion detection rate was 0.67 without a significant difference between Cartesian and radial sequences (figure of merit: 0.67 vs. 0.68, respectively, p = 0.876).
- Subjects
CONTRAST-enhanced magnetic resonance imaging; MAGNETIC resonance imaging; LIVER; HEPATOCELLULAR carcinoma
- Publication
European Radiology, 2023, Vol 33, Issue 6, p4378
- ISSN
0938-7994
- Publication type
Article
- DOI
10.1007/s00330-022-09336-8