We found a match
Your institution may have access to this item. Find your institution then sign in to continue.
- Title
Experimental Investigation of Precast Concrete Insulated Sandwich Panels with Glass Fiber-Reinforced Polymer Shear Connectors.
- Authors
Tomlinson, Douglas; Fam, Amir
- Abstract
A new precast concrete insulated sandwich wall panel with glass fiber-reinforced polymer (GFRP) shear connectors is investigated. The GFRP connectors, which connect the two outer concrete wythes, are embedded in floating concrete studs to reduce their shear deformations within the interstitial insulation layer. Nine full-scale, 2400 x 1550 x 260 mm (94.5 x 61 x 10.2 in.) panels were tested in four-point bending to examine the effects of varying the sizes and spacing of GFRP connectors, as well as the contribution of adhesion and friction bond between concrete and insulation. As the reinforcement ratio of GFRP connectors increased from 0.026 to 0.098% in these partially composite panels, the ultimate loads increased from 58 to 80% of the strength of an equivalent fully composite panel. Within this range, adhesion and friction contributed 44 to 59% of the ultimate loads. Despite the small embedment lengths of the sand-coated GFRP straight connectors in the wythes, no pullout failure occurred and all connectors fractured during the tests.
- Subjects
PRECAST concrete; GLASS fibers; POLYMER research; MEASUREMENT of shear (Mechanics); COMPOSITE materials research
- Publication
ACI Structural Journal, 2014, Vol 111, Issue 3, p595
- ISSN
0889-3241
- Publication type
Article
- DOI
10.14359/51686621