We found a match
Your institution may have access to this item. Find your institution then sign in to continue.
- Title
Discharge Through a Vertical, Rectangular Orifice.
- Authors
Viher, R.; Gjetvaj, G.
- Abstract
In this paper, the derivation of a formula is presented to determine the time taken for the discharge of an open tank through a vertical, rectangular orifice. This formula allows a simpler and more accurate determination of the discharge time. The formula obtained by the integration of velocity distribution was checked using a numerical model. It is shown the great correspondence between the derived formula and a formula for small orifices, regardles of whether the orifice is small or not, except in the cases where the height of orifice is much greater than the height of water level from the upper edge of the orifice. The presented formula takes into account the velocity distribution down the orifice and can be treated as a formula for all rectangular orifices.
- Subjects
VELOCITY distribution (Statistical mechanics); FLUID dynamics
- Publication
International Review of Chemical Engineering - Rapid Communications, 2022, Vol 14, Issue 1, p14
- ISSN
2035-1755
- Publication type
Article
- DOI
10.15866/ireche.v14i1.23217