<bold>Objectives: </bold>To investigate the efficacy of drug-coated balloon (DCB) for calcified coronary lesions.<bold>Background: </bold>Calcified coronary lesions is associated with poor clinical outcomes after revascularization. Recently, DCB is emerging as an alternative strategy for de novo coronary lesions. However, reports describing the efficacy of DCB for calcified coronary lesions are limited.<bold>Methods: </bold>A total of 81 patients (96 lesions) who electively underwent DCB treatment for de novo coronary lesions were enrolled: 46 patients (55 lesions) in the calcified group and 35 patients (41 lesions) in the non-calcified group. Angiographic follow-up data and clinical outcomes after the procedure were evaluated.<bold>Results: </bold>The diameter of the DCB used was 2.5 ± 0.5 mm. No bail-out stenting was observed after DCB treatment. Rotational atherectomy was used in 82% of lesions in the calcified group. Follow-up angiography (median, 6.5 months after intervention) was performed for 59 patients (30 in the calcified group and 29 in the non-calcified group). Late lumen loss and rates of restenosis were comparable between the groups (0.03 mm in the calcified group vs -0.18 mm in the non-calcified group, P = 0.093 and 13.9% vs 3.03%, P = 0.095, respectively). The survival rates for target lesion revascularization free survival and major adverse cardiac events at 2 years were comparable between the groups (85.3% vs 93.4%, P = 0.64 and 81.4% vs 88.5%, P = 0.57, respectively).<bold>Conclusion: </bold>Calcified coronary lesions might dilute the effect of DCB. However, clinical outcomes in the calcified group were similar to those in the non-calcified group.
- Subjects
JAPAN; DRUG efficacy; PHARMACEUTICAL technology; DRUG coatings; REVASCULARIZATION (Surgery); ENDARTERECTOMY; CORONARY heart disease surgery; CORONARY restenosis prevention; CORONARY restenosis; CORONARY disease; MYOCARDIAL revascularization; TIME; TRANSLUMINAL angioplasty; TREATMENT effectiveness; DRUG-eluting stents; CALCINOSIS; EQUIPMENT &; supplies; DIAGNOSIS
- Publication
Journal of Interventional Cardiology, 2018, Vol 31, Issue 4, p436
- ISSN
0896-4327
- Publication type
journal article
- DOI
10.1111/joic.12484