We found a match
Your institution may have access to this item. Find your institution then sign in to continue.
- Title
The effect of human blood on the setting and surface micro-hardness of calcium silicate cements.
- Authors
Song, Minju; Yue, Wonyoung; Kim, Soyeon; Kim, Wooksung; Kim, Yaelim; Kim, Jeong-Woong; Kim, Euiseong
- Abstract
Objectives: The purpose of the present study was to evaluate the effects of human blood on the setting and microhardness of calcium silicate cements. Materials and methods: Three types of silicate-based cements were used: ProRoot MTA (PMTA), OrthoMTA (OMTA), and RetroMTA (RMTA). Mixed cement was placed into polyethylene molds with lengths of 2 and 4 mm. After storage for 4 days under three different storage conditions, i.e., saline, saline after 5 min of human blood, and human blood, the polyethylene molds were removed. With the specimens set, the surface microhardness was measured using a Vickers microhardness tester, crystalline structure was analyzed with X-ray diffraction (XRD), and the surface characteristics were examined with scanning electron microscopy (SEM). Results: All specimens of 4 mm in length were set with all materials, and the blood groups exhibited lower microhardnesses than did the saline groups ( p < 0.05). Among the 2-mm specimens that were stored in blood, the numbers of specimens that set were significantly different across the materials ( p < 0.001). Regarding the microhardnesses of the RMTA and OMTA groups, there were no significant differences between storage conditions. For the PMTA group, only one specimen that was set in the blood group exhibited reduced microhardness. XRD showed changes of crystalline structure in the PMTA and OMTA blood group, whereas RMTA did not. SEM analysis revealed more rounded and homogeneous structures and demonstrated a clear lack of acicular or needle-like crystals in the PMTA and OMTA blood groups, while RMTA did not reveal substantial differences between the saline- and blood-stored groups. Conclusion: Blood contamination detrimentally affected the surface microhardnesses of all materials; furthermore, among the 2-mm specimens, blood contamination interfered with normal setting. Therefore, RMTA might be a more suitable choice when blood contamination is unavoidable due to limited depth. Clinical relevance RetroMTA might be a more suitable choice in situations in which blood contamination is unavoidable.
- Subjects
BLOOD; CALCIUM silicates; MICROHARDNESS; POLYETHYLENE; X-ray diffraction; SCANNING electron microscopes
- Publication
Clinical Oral Investigations, 2016, Vol 20, Issue 8, p1997
- ISSN
1432-6981
- Publication type
Article
- DOI
10.1007/s00784-015-1693-z